Snap-on 5000-3 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Werkzeug Snap-on 5000-3 herunter. Snap-On 5000-3 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - SURETEST AND 600TL

SURETEST AND 600TL Model 5000-3 Torque Calibration System USER’S MANUAL

Seite 2 - TABLE OF CONTENTS

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 CHAPTER 2 Functional Description and Specifications The CDI 5000-3 is CDI’s next generation Tor

Seite 3

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 SURETEST BASE UNIT Front Panel Figure 2-2 SURETEST Front Panel A- Membrane Function

Seite 4 - Using this Manual

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 Display A 240 x 64 Full-featured Graphic LCD is used to provide versatile and clear displays of s

Seite 5 - CAUTION

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 The SURETEST returns to the default menu from the measurements mode in the event there is no selec

Seite 6 - Safety Information

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 3. Select Language Selects either English, German (Deutsch), French (François), Spanish (Español)

Seite 7

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 6. Edit Limits Sets up high torque limit preset. (-->) (F4) to go Down 1 line. Sets up low

Seite 8 - Introduction

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 9. Edit Parameters Sets up serial communications protocol. Sets delay (in ms) per character u

Seite 9

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 Sets up memory clear options in RECALL mode. Recalls memory data to display. Format (F3) calls S

Seite 10 - CHAPTER 2

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 SURETEST BASE UNIT Rear Panel (Input/Output) Figure 2-3 SURETEST Rear Panel A - Solenoid

Seite 11 - Front Panel

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 F- PRINTER PORT (DB-9P) PIN FUNCTION 2 Receive 3 Transmit 5 Ground G- OPTIONAL (DB-9P) PIN

Seite 12 - Power Up Sequence

TABLE OF CONTENTS Safety Information I Introduction 1-1 Functional Description and Specifications 2-1 Functional Descriptions

Seite 13 - Setup Mode

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 SURETEST Transducers SURETEST transducers provide industry standard square drives. They feature

Seite 14

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 Specifications SURETEST TORQUE CALIBRATION SYSTEM Specifications System Accuracy ±0.25% of readin

Seite 15

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 Power Requirements 100-230 VAC, 50-60 HZ, 50 W, automatic voltage selection. Fused at 3.15 A. E

Seite 16

FUNCTIONAL DESCRIPTION AND SPECIFICATIONS CHAPTER 2 SURETEST Transducer/Display Resolution mkg cmkg ft. lb. in. lb. in. oz. Nm dNm cN

Seite 17

SETUP AND PROGRAMMING CHAPTER 3 CHAPTER 3 SETUP AND PROGRAMMING CDI 5000-3 TORQUE CALIBRATION SYSTEM SETUP Figure 3-1: CDI 5000-3 Torque Tester/

Seite 18 - Rear Panel (Input/Output)

SETUP AND PROGRAMMING CHAPTER 3 Setting Up the CDI 5000-3 Torque Calibration System 1. Bolt the loader to a sturdy location. 2. Install Pivot tub

Seite 19 - F- PRINTER PORT (DB-9P)

SETUP AND PROGRAMMING CHAPTER 3 SURETEST Base Unit Controls Refer to the illustration below when performing the power-up and programming procedure

Seite 20 - SURETEST Transducers

SETUP AND PROGRAMMING CHAPTER 3 4-in-1 Transducer Installation When a 4-in-1 transducer is installed, the following is displayed: The

Seite 21 - Specifications

SETUP AND PROGRAMMING CHAPTER 3 Setup Programming Setting up Date and Time 1. Press (Setup). 2. Scroll Down (↓) to select Clock Adjus

Seite 22

SETUP AND PROGRAMMING CHAPTER 3 3. Press Enter (↵). The display reads: 4. Press --> (F5) or <-- (F6) to select High or Low

Seite 23 - SURETEST

SURETEST Base Unit Calibration 5-11 Gravitational Effects 5-14 Correction Factors on Test Weights 5-14 Gravitational Charts 5-1

Seite 24 - SETUP AND PROGRAMMING

SETUP AND PROGRAMMING CHAPTER 3 To Program AUTO CLEAR, STORE, or SEND: 1. Press (Setup). 2. Scroll Down (↓) to select Auto settings

Seite 25

SETUP AND PROGRAMMING CHAPTER 3 Clear Single Memory Location Use the procedure in this section to clear a single memory location. 1. Press

Seite 26 - SURETEST Base Unit Controls

SETUP AND PROGRAMMING CHAPTER 3 1. Press Setup 2. Scroll Down (↓) to select Edit Parameters 3. Press Enter (↵) the display read: 4. Press --&

Seite 27

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 CHAPTER 4 CDI 5000-3 TORQUE CALIBRATION SYSTEM SETUP This chapter contains information on how to test,

Seite 28 - Setup Programming

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Dial and Bending Beam Torque Wrenches and Screwdrivers Be sure the SURETEST transducer is capable of handl

Seite 29 - Set-up AUTO Settings

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Adjustable or Preset “Click” Wrenches and Screwdrivers Be sure the SURETEST transducer is capable of handl

Seite 30 - DATA LIST Memory

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Testing Power Tools The dynamic torque characteristic of a power tool and the static torque applied when u

Seite 31

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Figure 4-1: Power Tool Test Setup A - Power Tool B - Joint Rate Simulator C - Transducer 7. Coupl

Seite 32

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 tool clutch slips. Be careful not to add torque by turning the tool by hand. 14. Release the torque an

Seite 33 - CHAPTER 4

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Statistical Analysis The SURETEST Base Unit accumulates torque measurements in a data list. The list is c

Seite 34 - WARNING

Using this Manual This manual contains instructions for use and setup of the SURETEST 5000-3 Torque Calibration System. A table of contents and a t

Seite 35

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Printing Statistical Analysis 1. Press Data (F1) in select Transducer screen or (F2) in measurements mode

Seite 36 - Non-Impact Tools

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 ** R E S U L T ** Data : 0010 Max : 254.89 in-lb Min : 251.49 in-lb Range : 3.4039 in-lb Mean : 253

Seite 37

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 Displaying or Downloading Data List Torque measurements stored in the data list also include a date and t

Seite 38

TORQUE CALIBRATION SYSTEM SETUP CHAPTER 4 How to Use Analog Output (Rear Panel BNC Connector) Analog Output on the SURETEST provides a real time vo

Seite 39 - Statistical Analysis

CALIBRATION CHAPTER 5 CHAPTER 5 CALIBRATION The SURETEST Torque Calibration System is factory calibrated using precision torque test arms, ce

Seite 40 - SPC PRINT-OUT

CALIBRATION CHAPTER 5 Torque Under 250 ft. lb. Mount the calibration block at the center of the stand with two 1/2-13 socket head cap screws w

Seite 41

CALIBRATION CHAPTER 5 WARNING Always position the 40" arm over the front of the stand as shown. Never extend the test arm behind the sta

Seite 42 - Displaying Data List

CALIBRATION CHAPTER 5 The 4-in-1 transducer may also be mounted to the calibration stand, shown in Figure 5-1, using the standoff fixture and

Seite 43

CALIBRATION CHAPTER 5 Suggested Transducer Calibration Check Points, Bars, Hangers and Weights (Sheet 1 of 2) Part Bar Hanger

Seite 44 - CALIBRATION

CALIBRATION CHAPTER 5 Suggested Transducer Calibration Check Points, Bars, Hangers and Weights (Sheet 2 of 2) Part Bar Hanger

Seite 45 - Torque Over 250 ft. lb

DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury to the operator or to bystanders. W

Seite 46

CALIBRATION CHAPTER 5 Torque Calibrations SURETEST New Transducer Calibration Improper calibration can result in torque measurement errors

Seite 47 - Quick Check

CALIBRATION CHAPTER 5 6. Enter the following code into the display using the Cursor Keys: 5222 ( Left (←), Right (→) to select digit ; Up

Seite 48

CALIBRATION CHAPTER 5 Press Unit (F2) key and select the desired torque unit. 10. Using the Up (↑) and Down (↓) Cursor keys, enter the Ful

Seite 49

CALIBRATION CHAPTER 5 13. Press (Accept) to accept the calibration value (1st Cal point). Apply 20% Torque = 10 in. lb. 14. Press

Seite 50

CALIBRATION CHAPTER 5 22. All readings show minus sign (-). Press F1 twice to return to measurement mode. SURETEST Base Unit Calibrat

Seite 51 - Calibration CW:

CALIBRATION CHAPTER 5 4. Enter the following code into the display using the Cursor Keys: 5111. Then press (

Seite 52

CALIBRATION CHAPTER 5 Example: 08.0622 mV 7. Program the measured voltage into the SURETEST Indicator as demonstrated in the example,

Seite 53 - Calibration CCW:

CALIBRATION CHAPTER 5 Gravitational Effects Correction Factors on Test Weights Weights used in torque calibration are affected by their acce

Seite 54 - Equipment

CALIBRATION CHAPTER 5 Gravitational Charts The charts in this section are taken from CRC Handbook of Chemistry and Physics, 58th Edition.

Seite 55 - Calibrate tester

MANUAL LOADER CHAPTER 6 600TL - 600 ft. lb. Capacity Manual Loader The 600TL Manual Loader is designed as an integral component of the CDI 500

Seite 56

SAFETY INFORMATION Safety Information Important Safety Instructions This manual contains important safety and operating instructions for CDI 5000-3

Seite 57 - Gravitational Effects

MANUAL LOADER CHAPTER 6 Torque Tester/Calibrator Figure 6-1: Installation multiple transducers A- Quick release pin (Transducer) B- 4-in-1 T

Seite 58 - Gravitational Charts

MANUAL LOADER CHAPTER 6 Drive Adaptor A drive adaptor couples the wrench to the transducer. Low torque 2000 series transducers use an internal-

Seite 59 - Manual Loader

MANUAL LOADER CHAPTER 6 Figure 6-2 Set up for Dial indicating, Deflection Beam and Micro-Adjustable Torque Wrenches. 1- Transducer Mounting A

Seite 60 - IMPORTANT

MANUAL LOADER CHAPTER 6 Types of Loader Testing Torque Driver Testing An optional torque screwdriver testing kit, is available for use in testing

Seite 61

ACCESSORIES APPENDIX A Appendix A Accessories, included SURETEST 5000-3 Torque Calibration System Components Component Description 5000-ST SURE

Seite 62

ACCESSORIES APPENDIX A Appendix A Accessories, optional Component Description 2000-4-02 1/4" ext. drive 5 – 50 in. oz. Transducer

Seite 63 - Torque Driver Testing

ACCESSORIES APPENDIX A Component Description 2000-50-1 Cable, Indicator to PC 950-79 Foot Pedal Switch (Data Send foot swi

Seite 64 - Accessories, included

ACCESSORIES APPENDIX A Calibration Accessories Calibration of the SURETEST Indicator and 2000 series transducers is recommended at least every 1 y

Seite 65 - Accessories, optional

19220 San Jose Ave. City of Industry, CA 91748-1497 FORM 20-2100-CDI

Seite 66 - Component Description

SAFETY INFORMATION so the torque and load values are indicated on the display. The safety relays only work when the power is on. Flying parti

Seite 67 - Calibration Accessories

INTRODUCTION CHAPTER 1 CHAPTER 1 Introduction The SURETEST is a laboratory grade instrument that provides TORQUE measurements. Although desig

Seite 68 - 19220 San Jose Ave

INTRODUCTION CHAPTER 1 The SURETEST operates directly from any AC power line between 100 VAC to 230 VAC, 50–60 Hz without the need for switch sele

Kommentare zu diesen Handbüchern